Quick Jump

Pump Cables

Type MFL3 Motor Flat Lead


  1. Solid uncoated copper conductor with
  2. Double layer of Kapton™ tape bonded to the conductor
  3. EPDM insulation bonded to the Kapton
  4. Lead Sheath
  5. Longitudinally applied, rubber backed, fabric bedding tape
  6. Monel Armor
Low profile Motor Flat Lead (MFL3) cables are rated 4 or 5 kV for operating temperatures up to 450ºF. They provide excellent performance in highly corrosive wells. These cables feature lead sheaths, which provide a superior barrier to the damaging effects of hydrogen sulfide.

Optional Features
Galvanized Steel Armor    Stainless Steel Armor


Catalog Numbers


 

 

Part

Number

 

kV

Conductor

Size

AWG

(mm2)

Conductor

O.D.

Inches

(mm)

Insulation

O.D.

Inches

(mm)

Overall

O.D.

Inches

(mm)

 

Weight

lbs./ft.

(kg/m)

1MFL3044-010

4

4

(21.1)

.20

(5.2)

.31

(8.0)

1.30 x .50

(33.0 x 12.7)

1.5

(2.2)

1MFL3064-010

4

6

(13.3)

.16

(4.1)

.27

(6.9)

1.17 x .46

(29.7 x 11.7)

1.2

(1.8)

1MFL3045-010

5

4

(21.1)

.20

(5.2)

.35

(8.9)

1.41 x .54

(35.8 x 13.7)

1.7

(2.5)

1MFL3065-010

5

6

(13.3)

.16

(4.1)

.31

(7.9)

1.28 x .50

(32.5 x 12.6)

1.4

(2.1)

Note: All dimensions are subject to normal manufacturing tolerances


Application Data


Conductor operating temperature recommended guidelines are based on Neher-McGrath calculations presented in IEEE Std 1018 and 1019.