Quick Jump
|
15kV Aluminum Conductor 90°C (UL) Rating
Conductor Shield – Non-Conducting Permashield®
Stress Control Layer
Insulation – Discharge Resistant EPR Insulation
Insulation Shield – Extruded Free Stripping
Semi-Conducting Layer
Concentric Wires – One-third or Full Neutral
Jacket – Insulating Polyethylene (PE) with 3 Red
stripes, Semi-Conducting Available
|
Catalog Numbers
|
One-Third Neutral |
Catalog Number Suffix =
A3200
175 mil Insulation (100%)* |
Catalog Number Suffix =
C3200
220 mil Insulation (133%)* |
|
CATALOG
NO. PREFIX |
SIZE
(AWG/kcmil) |
No Of
Strands |
Copper
Neutral
Wires
(No-#AWG) |
O.D. Over
Insulation
(Inches) |
O.D. Over
Jacket
(Inches) |
Cable
Weight
(lbs/ft) |
O.D. Over
Insulation
(Inches) |
O.D. Over
Jacket
(Inches) |
Cable
Weight
(lbs/ft) |
|
102S15- |
2 |
SOL |
6 - #14 |
0.654 |
0.962 |
0.397 |
0.746 |
1.054 |
0.466 |
|
102A15- |
2 |
7 |
6 - #14 |
0.681 |
0.989 |
0.411 |
0.773 |
1.081 |
0.482 |
|
101S15- |
1 |
SOL |
6 - #14 |
0.685 |
0.993 |
0.427 |
0.777 |
1.085 |
0.498 |
|
101A15- |
1 |
19 |
6 - #14 |
0.709 |
1.017 |
0.441 |
0.801 |
1.109 |
0.514 |
|
111S15- |
1/0 |
SOL |
6 - #14 |
0.721 |
1.029 |
0.464 |
0.813 |
1.121 |
0.537 |
|
111A15- |
1/0 |
19 |
6 - #14 |
0.748 |
1.056 |
0.480 |
0.840 |
1.148 |
0.555 |
|
121S15- |
2/0 |
SOL |
7 - #14 |
0.761 |
1.069 |
0.522 |
0.853 |
1.161 |
0.598 |
|
121A15- |
2/0 |
19 |
7 - #14 |
0.791 |
1.099 |
0.539 |
0.883 |
1.191 |
0.617 |
|
141A15- |
4/0 |
19 |
11 - #14 |
0.894 |
1.202 |
0.711 |
0.986 |
1.294 |
0.798 |
|
125A15- |
250 |
37 |
13 - #14 |
0.958 |
1.266 |
0.805 |
1.050 |
1.378 |
0.916 |
|
135A15- |
350 |
37 |
18 - #14 |
1.061 |
1.389 |
1.032 |
1.153 |
1.481 |
1.134 |
|
150A15- |
500 |
37 |
16 - #12 |
1.189 |
1.551 |
1.339 |
1.281 |
1.709 |
1.522 |
|
175A15- |
750 |
61 |
24 - #12 |
1.378 |
1.806 |
1.916 |
1.47 |
1.898 |
2.048 |
|
190A15- |
1000 |
61 |
20 - #10 |
1.527 |
2.027 |
2.439 |
1.619 |
2.119 |
2.585 |
|
Full Neutral |
Catalog Number Suffix =
A1200
175 mil Insulation (100%)* |
Catalog Number Suffix =
C1200
220 mil Insulation (133%)* |
|
102S15- |
2 |
SOL |
10 - #14 |
0.654 |
0.962 |
0.449 |
0.746 |
1.054 |
0.518 |
|
102A15- |
2 |
7 |
10 - #14 |
0.681 |
0.989 |
0.463 |
0.773 |
1.081 |
0.534 |
|
101S15- |
1 |
SOL |
13 - #14 |
0.685 |
0.993 |
0.518 |
0.777 |
1.085 |
0.589 |
|
101A15- |
1 |
19 |
13 - #14 |
0.709 |
1.017 |
0.532 |
0.801 |
1.109 |
0.605 |
|
111S15- |
1/0 |
SOL |
16 - #14 |
0.721 |
1.029 |
0.595 |
0.813 |
1.121 |
0.668 |
|
111A15- |
1/0 |
19 |
16 - #14 |
0.748 |
1.056 |
0.611 |
0.840 |
1.148 |
0.686 |
|
121S15- |
2/0 |
SOL |
20 - #14 |
0.761 |
1.069 |
0.692 |
0.853 |
1.161 |
0.768 |
|
121A15- |
2/0 |
19 |
20 - #14 |
0.791 |
1.099 |
0.709 |
0.883 |
1.191 |
0.787 |
|
141A15- |
4/0 |
19 |
20 - #12 |
0.894 |
1.236 |
0.985 |
0.986 |
1.328 |
1.073 |
| |
|
|
|
|
|
|
|
|
|
|
|
Five minute AC Final Test Voltages
175 mil Insulation Level: 35kV
220 mil Insulation Level: 44kV
|
|
|
 |
|