POWER
CABLES - TYPE MV 105
5kV
SHIELDED (SPS) 105°C Rating
CONDUCTOR
-
Class "B" Copper Strand (Aluminum
Conductors Available)
CONDUCTOR SHIELD - Unique Permashield®
System
INSULATION - Exclusive Corona-Immune Insulation
INSULATION SHIELD - Free Stripping Semiconducting
Layer
METALLIC SHIELD - 5 mil Copper Tape,
20% Overlap (Optional
Longitudinal Corragated Copper Shield Available)
JACKET - PVC (Thermosetting Kerite FR Available)
SINGLE
CONDUCTOR
| |
CATALOG
NUMBER SUFFIX |
|
| C4400 |
| 115
Mil Insulation |
| CATALOG
|
Size
|
No.
|
O.D.
Over |
Jacket
|
Cable
|
| NO.
|
(AWG/
|
of
|
Insul.
|
Thickness
|
O.D.
|
Weight
|
| PREFIX
|
kcmil)
|
Str.
|
(Inches)
|
(Mils)
|
(Inches)
|
(Lbs./Kft)
|
| |
|
|
|
|
|
|
| 106C05-
|
6
|
7
|
0.47
|
60
|
0.69
|
312
|
| 104C05-
|
4
|
7
|
0.52
|
60
|
0.74
|
384
|
| 102C05-
|
2
|
7
|
0.58
|
60
|
0.80
|
492
|
| 101C05-
|
1
|
19
|
0.62
|
60
|
0.84
|
565
|
| 111C05-
|
1/0
|
19
|
0.66
|
60
|
0.89
|
691
|
| 121C05-
|
2/0
|
19
|
0.70
|
80
|
0.96
|
801
|
| 131C05-
|
3/0
|
19
|
0.75
|
80
|
1.01
|
936
|
| 141C05-
|
4/0
|
19
|
0.81
|
80
|
1.07
|
1104
|
| 125C05-
|
250
|
37
|
0.86
|
80
|
1.13
|
1257
|
| 135C05-
|
350
|
37
|
0.97
|
80
|
1.23
|
1625
|
| 150C05-
|
500
|
37
|
1.10
|
80
|
1.38
|
2185
|
| 175C05-
|
750
|
61
|
1.29
|
80
|
1.57
|
3077
|
| 190C05-
|
1000
|
61
|
1.45
|
80
|
1.73
|
3930
|
| 192C05-
|
1250
|
91
|
1.64
|
110
|
2.02
|
5058
|
| 195C05-
|
1500
|
91
|
1.76
|
110
|
2.14
|
5917
|
| 197C05-
|
1750
|
127
|
1.87
|
110
|
2.25
|
6777
|
| 199C05-
|
2000
|
127
|
1.98
|
110
|
2.36
|
7615
|
†† 140 Mil
Insulation for 1250 through 2000 kcmil. |
FIVE MINUTE AC FINAL TEST VOLTAGES
|
Conductor
Size
|
|
|
(AWG
/ kcmil)
|
AC
(kV)
|
|
#6 - 1000
|
23
|
|
1250 -
2000
|
28
|
|
CATALOG NUMBER
EXAMPLE: |
106C05-C4400
= #6 AWG (7) CU 5kV, SPS 115 mil Kerite Extruded Semicon 5 mil
CU Tape, 60 mil PVC Jacket. |
POWER
CABLES - TYPE MV 105
5kV
SHIELDED (SPS) 105°C Rating
CONDUCTOR -
Class "B" Copper Strand (Aluminum
Conductors Available)
CONDUCTOR SHIELD - Unique Permashield System
INSULATION - Exclusive
Corona-Immune Insulation
INSULATION SHIELD - Free Stripping Semiconducting
Layer
METALLIC SHIELD - 5 mil Copper Tape,
20% Overlap (Optional
Longitudinal Corragated Copper Shield Available)
JACKET - Overall PVC (Black-STD, Colors
Available; Optional Individual Jackets Available)
THREE
CONDUCTOR OVERALL PVC JACKET
CATALOG NUMBER SUFFIX
C4052
115 Mil Insulation |
| CATALOG
|
Size
|
No.
|
Ground
|
O.D.
Over |
Overall
Jacket |
Cable
|
| NO.
|
(AWG/
|
of
|
Conductor
|
Insul.
|
Thickness
|
O.D.
|
Weight
|
| PREFIX
|
kcmil)
|
Str.
|
(No.-AWG)
|
(Inches)
|
(Mils)
|
(Inches) |
(Lbs./Kft) |
| |
|
|
|
|
|
|
|
| 306C05-
|
6
|
7
|
1
- #6 |
0.47
|
80
|
1.40
|
1047
|
| 304C05-
|
4
|
7
|
1
- #6 |
0.52
|
80
|
1.50
|
1285
|
| 302C05-
|
2
|
7
|
1
- #6 |
0.58
|
80
|
1.63
|
1649
|
| 301C05-
|
1
|
19
|
1
- #4 |
0.62
|
80
|
1.71
|
1884
|
| 311C05-
|
1/0
|
19
|
1
- #4 |
0.66
|
110
|
1.86
|
2294
|
| 321C05-
|
2/0
|
19
|
1
- #4 |
0.70
|
110
|
1.96
|
2655
|
| 331C05-
|
3/0
|
19
|
2
- #6 |
0.75
|
110
|
2.07
|
3106
|
| 341C05-
|
4/0
|
19
|
2
- #6 |
0.81
|
110
|
2.19
|
3648
|
| 325C05-
|
250
|
37
|
2
- #6 |
0.86
|
110
|
2.31
|
4149
|
| 335C05-
|
350
|
37
|
1
- #2 |
0.97
|
110
|
2.53
|
5340
|
| 350C05-
|
500
|
37
|
1
- #1 |
1.10
|
140
|
2.92
|
7363
|
| 375C05-
|
750
|
61
|
1
- #1/0 |
1.29
|
140
|
3.33
|
10332
|
| 390C05-
|
1000
|
61
|
1
- #1/0 |
1.45
|
140
|
3.68
|
13088
|
POWER
CABLES - TYPE MV 105
5kV
SHIELDED (SPS) 105°C Rating
CONDUCTOR -
Class "B" Copper Strand (Aluminum
Conductors Available)
CONDUCTOR SHIELD - Unique Permashield System
INSULATION - Exclusive
Corona-Immune Insulation
INSULATION SHIELD - Free Stripping Semiconducting
Layer
METALLIC SHIELD - 5 mil Copper Tape,
20% Overlap
JACKET - Overall PVC (Black-STD, Colors
Available; Optional Individual Jackets Available)
THREE
CONDUCTOR OVERALL PVC JACKET
GALVANIZED STEEL INTERLOCKED ARMOR (OPTIONAL CONTINOUS
CORROGNATED WELDED ALUMINUM ARMOR - CCW AVAILABLE)
CATALOG
NUMBER SUFFIX
C4055
115 Mil Insulation† |
| CATALOG
|
Size
|
No.
|
Ground
|
O.D.
Over |
Overall
Jacket |
Cable
|
| NO.
|
(AWG/
|
of
|
Conductor
|
Armor
|
Thickness
|
O.D.
|
Weight
|
| PREFIX
|
kcmil)
|
Str.
|
(No.-AWG)
|
(Inches)
|
(Mils)
|
(Inches) |
(Lbs./Kft) |
| |
|
|
|
|
|
|
|
| 306C05-
|
6
|
7
|
1
- #6 |
1.48
|
50
|
1.59
|
1438
|
| 304C05-
|
4
|
7
|
1
- #6 |
1.58
|
50
|
1.69
|
1706
|
| 302C05-
|
2
|
7
|
1
- #6 |
1.70
|
60
|
1.84
|
2147
|
| 301C05-
|
1
|
19
|
1
- #4 |
1.79
|
60
|
1.92
|
2408
|
| 311C05-
|
1/0
|
19
|
1
- #4 |
1.87
|
60
|
2.00
|
2896
|
| 321C05-
|
2/0
|
19
|
1
- #4 |
1.97
|
60
|
2.10
|
3291
|
| 331C05-
|
3/0
|
19
|
2
- #6 |
2.08
|
60
|
2.21
|
3781
|
| 341C05-
|
4/0
|
19
|
2
- #6 |
2.20
|
60
|
2.33
|
4367
|
| 325C05-
|
250
|
37
|
2
- #6 |
2.32
|
60
|
2.45
|
4912
|
| 335C05-
|
350
|
37
|
1
- #2 |
2.54
|
75
|
2.71
|
6266
|
| 350C05-
|
500
|
37
|
1
- #1 |
2.86
|
75
|
3.03
|
8232
|
| 375C05-
|
750
|
61
|
1
- #1/0 |
3.27
|
85
|
3.46
|
11408
|
| 390C05-
|
1000
|
61
|
1
- #1/0 |
3.62
|
85
|
3.81
|
14284
|
†For diameter over the insulation, refer
to Three Conductor PVC Jacket table above.
Note: Underwriters Laboratories additional labeling for cable tray
(CT), sunlight and oil resistance is also available as applicable.
|